Building Specifications

Built in 2007, this 254,200 square foot industrial building is in excellent condition and offers 80,880 square feet for lease.  The space is well-suited for a wide variety of distribution and manufacturing operations.  Mericle’s in-house Design and Construction departments will customize the space to your exact needs.

Size

SIZE

  • Available Space: 80,880 SF within an existing 254,200 SF building.
  • Tenant space availability ranges from 31,108 SF to 80,880 SF.
  • Acreage: 25.05 acres
  • Available Space Dimensions: 260’ (length) x 310’ (depth)
  • Building Dimensions: 820’ (length) x 310’ (depth)
  • Main Office: Approximately 3,553 SF
Building and Construction

Building Construction

  • Floor: 6” thick concrete floor slab reinforced with welded steel mats.
  • Roof: MR-24 standing seam metal roof system.
  • Exterior Walls: Architectural masonry, aluminum/glazing entrance systems and metal wall panels with insulation.
  • Ceiling Height: 33’-4” clear structural height at low eave, and 36’-8” clear structural height at ridge.
  • Column Spacing: 40’ x 50’ bay spacing with a 60’ deep staging bay at the loading dock.
Trailer Loading

Loading

  • Dock Equipment: Twelve (12) 9’ x 10’ vertical-lift dock doors with 30,000 lb capacity Rite-Hite mechanical levelers with bumpers, Frommelt dock seals, and dock lights.
  • One (1) 12’ w x 14’ h vertical-lift insulated steel drive-in door with a 14’-0” wide x 40’-0” long, 50,000 lb capacity precast ramp with curbs and guard rails.
  • 8’ wide concrete dolly pad.
  • 8” thick reinforced concrete dock apron.
Utilities

Utilities

  • Warehouse HVAC: High-efficiency, suspended, gas-fired unit heaters. One (1) Air Exchange/Hr. system provided.
  • Main Office HVAC: Gas/electric packaged rooftop unit.
  • Electrical Service: Two (2) 800 Amp, 277/480 Volt, 3-Phase, 4 wire, 60 hz electrical service, total capacity of 1600 Amps.
  • Warehouse Lighting: Energy-efficient fluorescent t-bay fixtures with lighting levels of 18 -22 fc average.
  • Office Lighting: 2 x 4 drop-in, fluorescent troffers with prismatic lenses.
  • Fire Protection: Early Suppression Fast Response (ESFR) sprinkler system.
  • Utilities: Domestic water, natural gas, power separately metered.
    Learn More
Parking

Parking

  • Vehicle Parking: On-site parking for up to 149 vehicles.
  • Trailer Parking: On-site parking for up to 34 trailers.
Location

Location

  • Less than one mile from I-81 and I-476.
  • More than 470,000 live within 20 miles of the park.
    Learn More

Information shown is purported to be from reliable sources. No representation is made to the accuracy thereof, and is submitted subject to errors, omissions, prior sale/lease, withdrawal notice, or other conditions.

Site Plan

Floor Plan

Office Plan